Battery Control Management System

BCMS

Integrated on-site
diagnosis and control unit

Real-time diagnosis, alerts, and control from M-BMS data.

On-site monitor, server linkage, and pack-level history management.

Real-time status diagnosisAlerts and risk judgmentActive function controlLocal and server operation
BCMS

SIZE

540×600×305

TYPE

Portable unit

DISPLAY

Monitor arm

LINK

M-BMS

01 · Characteristics

The hub for on-site judgment and operation

Receives M-BMS data and operates diagnosis, control, and history on site.

BCMS-centered operation

Receives M-BMS data and unifies diagnosis, control, and history.

Edge AI on-site analysis

Analyzes voltage, temperature, deviation, and anomaly patterns to judge on-site risk.

Bidirectional control

Issues M-BMS control commands from diagnosis results, linking PRA, relays, and outputs.

Local and remote operation

Direct on-site monitor check and server-based remote monitoring.

02 · Core Functions

From diagnosis to control and history

Supports on-site operation from live status through alerts, control, and history.

Real-time status diagnosis

  • Cell and pack voltage
  • Temperature and sensor status
  • Balancing analysis
  • Edge AI pattern analysis

Alerts and active control

  • Abnormal-state alerts
  • Diagnosis stop and restart
  • Output stop
  • Relay control
  • M-BMS command delivery

Operation and history

  • Live status screen
  • Event results
  • Communication logs
  • Pack-level history
  • Server report data

03 · Integration

Operations hub between M-BMS and server

BCMS is the on-site control node. Remote checks go through the server link.

Battery pack

Battery pack

Cell voltage and temperature

Output over CAN

M-BMS

M-BMS

Pack-status data collection

Control-command delivery

BCMS

BCMS

Diagnosis, logs, and control

Series, parallel, or standalone

Physical layer: serial link

Field monitor

BCMS operations screen

Live status, alerts, and control results

Server and remote

REST for BCMS linkage

Remote monitoring and command APIs

INPUT

Collected pack data

Voltage, current, temperature

State (standby, charge, discharge)

MAIN PROCESS

Analysis, diagnosis, log, control

Risk and anomaly detection

Control algorithms and state storage

OUTPUT

Field monitor and server data

Live screens and reports

Diagnosis and alarms

04 · Specifications

Low-profile body and adjustable monitor

Low-profile body and adjustable monitor

Body basis W 540 × D 600 × H 305 mm

Form factorPortable on-site diagnosis and control unit
Body sizeW 540 × D 600 × H 305 mm
Size basisMain body (monitor and arm excluded)
MobilityLow-profile structure with casters
DisplayBody-mounted monitor arm, position adjustable
Main inputM-BMS real-time data
Field outputBCMS monitoring program
Upstream linkServer, report, and API

Power, communication, and safety specs are finalized to site and equipment standards.

Need a BCMS operating configuration?

We propose a configuration covering on-site diagnosis, alerts, control, and history.